ISOCOM LTD: BSI9000 and CECC20000 Approved Manufacturer

Hutton Close, Crowther Ind Est, Washington, Tyne & Wear NE38 0AH, England
Email: enquiry@isocomoptocouplers.com - Tel: +44 (0)191 4166546 - Fax: +44 (0)191 4155055

Circuit
Features
Description
Absolute Maximum Ratings
Insulation Rated Parameters
Isolation Characteristics

Similar Optocouplers
Home Page


H11AV1X, H11AV2X, H11AV3X
OPTICALLY COUPLED ISOLATOR TRANSISTOR OUTPUT

Circuit

0884 VDE FEATURES

Rated Impulse Voltage (Transient Overvoltage): VIOTM=6 kVpeak
Insulation Test Voltage (Partial Discharge Test): VPD=1.4 kVpeak
Rated Insulation Voltage (RMS includes d.c.): VIOWM=600 VRMS (848 Vpeak)
Rated Recurring Peak Voltage (repetitive): VIORM=600 VRMS
Isolation Materials: According to UL 94
Creeping Current Resistance: According to VDE 0303 Part 1/06.84 (IEC 112)
Climatic Classification: 55/100/21 (IEC 68 Part 1)
Comparative Tracking Index: CTI 275 (VDE 0109/12.83*)
Pollution Degree: 2 (VDE 0109/12.83*)
(*Identical with VDE 0110 Part 1/01.89)

Description

The H11 AV series are optically coupled isolators consisting of a Gallium Arsenide infrared emitting diode and an NPN silicon phototransistor mounted in a standard 6-pin dial-in-line package. Surface Mount Option Available.
The product type number consists of the basic product type followed by the letter "X" which indicates VDE 0884 approval of the basic part. Letter "X" supercedes letter "V" which denoted the now obsolete VDE 0883 approval.
For 10mm lead spread requirement add suffix G.
For surface mount requirements add suffix SM.

Applications

These couplers meet the requirements of the following Equipment Standards:
VDE 0109/12.83, VDE 0110/01.89:
Circuits for safe protective separation against electrical shock according to safety class II (reinforced isolation).
Application class I-IV at mains voltages <= 300V.
Application class I-III at mains voltages <= 600V.
VDE 0804/05.89:
Telecommunication Apparatus and Data Processing
VDE 0805/05.90 (IEC 950):
Data Processing Equipment and Office Machines (Option G only).
VDE 0860/05.89 (IEC 65):
Safety for mains-operated electronic and related apparatus for household.
UL 1577/09.89:
Standard for Safety Optical isolated switch systems. Package type K.
BS 415/1990; IEC 65/1985:
Safety requirements for mains-operated electronic and related apparatus for household and similar general use. Class II applications.
EN 60950/1989:
Specification for safety of information technology equipment including electrical business equipment (Option G only).

Absolute Maximum Ratings (Ta=25°C)

Storage Temperatare:
Operating Temperature:
Lead Soldering:
Input-to-Output Insulation Test Voltage:
-55°C to +125°C
-55°C to +125°C
260°C for 10s, 2mm from case
6kVpeak (Transient Overvoltage, t=10s)

Output Transistor

Collector-emitter Voltage BVceo:
Emitter-base Voltage BVebo:
Collector-base Voltage BVcbo:
Collector Current:
Collector Current:
Power Dissipation:
Derate Linearly:
70V
7V
70V
50mA
100mA (tp <= 10ms, Duty Ratio 0.5)
150mW
2.00mW/°C above 25°C

Input Diode

Forward DC Current:
Reverse DC Voltage:
Peak Forward Current:
Power Dissipation:
Derate Linearly:
60mA
6V
3A (1µs p.w. 300pps)
100mW
1.33mW/°C above 25°C

Package

Total Power Dissipation:
Derate Linearly:
250mW
3.3mW/°C above 25°C

0884 VDE Maximum Safety Ratings

Input Diode Isi:
Output Transistor Psi:

Coupled Device
Inpulse Voltage Viotm:
Safety Temperature Tsi:
130mA max
265mW max


6kV MAX
200°C

This device is suitable for safe electrical isolation only within the maximum safety ratings. This must be ensured by protective circuits in the applications.

Note

This device is suitable for safe electrical isolation only within the maximum safety ratings. This must be ensured by protective circuis in the applictions

Insulation Rated Parameters (15°C to 35°C, 45-75% RH u.o.s.)

PARAMETER TEST CONDITIONS MIN MAX UNIT
LOT SAMPLE TESTING
Transient Overvoltage Rating (VIOTM) Fig 1. VIOTM=6kVpeak, TINI=10s No breakdown may occur
Partial Discharge Measurement Fig 1. VPD=1.05kVpeak TP=60s
5 pC
Insulation Resistance VIO=500Vdc, TAMB=25°C 1E12
Ohm
VIO=500Vdc, TAMB=100°C 1E11
Ohm
VIO=500Vdc, TSI=200°C (construction test only) 1E9
Ohm
100% ROUTINE TESTING
Partial Discharge Measurement Fig 2. VPD=1.4kVpeak, TP=1s
5 pC

INPUT PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
VF Forward Voltage IF=10mA 0.8
1.5 V
IF=10mA, TA=-55°C 0.9
1.7 V
IF=10mA, TA=+100°C 0.7
1.4 V
IR Reverse Current VR=6.0V

10 µA

Capacitance VR=0, f=1MHz
30
pF
OUTPUT
BVCEO Collector-emitter Voltage IC=1mA 70

V
BVEBO Emitter-base Voltage IE=0.1mA 7

V
BVCBO Collector-base Voltage IC=0.1mA 70

V
ICEO Collector-emitter Dark Current VCE=10V, IF=0

50 nA
CCE Collector-emitter Capacitance VCE=10V, f=1MHz
2
pF
COUPLED TEST CONDITIONS MIN TYP MAX UNIT
IC/IF DC Current Transfer Ratio IF=10mA, VCE=10V



H11AV1X 100
300 %
H11AV2X 50

%
H11AV3X 20

%
RIO Input-to-Output Isolation Resistance VIO=500V, (Note 1) 1000

Gohm
VCE(SAT) Collector-emitter Saturation Voltage IF=20mA, IC=2.0mA

0.4 V
CIO Capacitance Input to Output f=1MHz, (Note 1)

0.5 pF
tON Turn-on Time VCC=10V, IC=2mA

15 µs
tOFF Turn-off Time RL=100ohm

15 µs

Notes

1. Measured with input leads shorted together and output leads shorted together

Isolation Characteristics

DESCRIPTION SYMBOL CHARACTERISTIC
Installation Category (DIN VDE0109, Dec 1983, Table 1)
I-IV
I-III
IEC Climatic Category (DIN IEC 68 Part 1/09.80)
55/150/21
Pollution Degree (DIN VDE0109, Dec 1983)
2
Maximum Operating Isolation Voltage VIORM 630 V
Test Voltage Input/Output, Procedure B(1)
VPR=1.6 x VIORM, Sample Test with tP=1s, Partial Discharge<5pC
VPR 1000 V
Test Voltage Input/Output, Procedure A(1)
VPR=1.2 x VIORM, Type and Sampling Test with tP=60s, Partial Discharge<5pC
VPR 720 V
Maximum Permissable Overvoltage
Transient Overvoltage, tTR=10s, Procedure A(1)
VTR 6000 V
Isolation Resistance, TSI VI/O=500V RIS >=1 Gohm
Safety Maximum Ratings (max permissible ratings in case of a fault):
Package Temperature TSI 175 °C
Current (IF, PSI=0) ISI 400 mA
Power (Output or Total Power Dissipation) PSI 700 mW



Isocom takes great effort to ensure accurate data, but regrettably cannot be held liable for any error on its website. Visit File Lists to confirm old printouts are up-to-date.